DO NOT use pump to remove gasoline, oil or other fl, ammable liquids. On sailboats, location should be centered, Do not mount pump directly to hull. Do not mount pump directly to hull. All Rights Reserved. Tenez le botier dans une main, et appuyez sur la languette de verrouillage avec lautre. Before drilling be sure mounted pump will be correctly positioned, with pump nozzle pointing toward thru-hull connector. Motorpatronen behver inte avlgsnas vid monteringen. For automatic operation, use Attwood Automatic Float Switch (#4201 or 4202). (gur 1), Avlgsna pumphuset frn sockeln. 1.Anslut den positiva ledaren (brun) till strmbrytaren. Braun an positiv (Schalter) und schwarz an negativ. On sailboats, location should be centered over keel. berprfung des richtigen Motorgehuses: Siehe Tabelle der technischen Daten wegen der Teilenummer eines AustauschMotorgehuses. T1200 Tsunami Bilge Pump : Attwood Marine Note that there are restrictions on some products, and some products cannot be shipped to international destinations. 2.Montera skringshllaren max 72 tum (1,83 m) frn den positiva (+) batteripolen. 3/4" I.D. Ne pas monter la pompe directement sur la coque. Insrez la pompe dans la base en la faisant tourner dans le sens des aiguilles dune montre jusqu ce que la languette senclenche et lempche de tourner. 1.Damit die Montagelcher zugnglich werden, entfernen Sie den geschlitzten Sockel. (gur 2). Avlgsna sockelsilen fr att komma t monteringshlen. Complete kit to install manual bilge pump with 3/4" I.D. Anvnd en elektrisk standardglasskring av fordonstyp (SAE J554). This Attwood Bilge Pump carries a three (3) year warranty. Zur Installation ist es nicht notwendig, das Motorgehuse zu entfernen (Abbildung 2). Tragen Sie eine entsprechende wasserfeste Dichtungsmasse innen und auen auf den Flanschen der Rumpfdurchfhrung auf. An example of data being processed may be a unique identifier stored in a cookie. Attwood's Tsunami 500 GPH Replacement Motor Cartridge for use with the Tsunami T500 Bilge Pump. Percez trois orices de guidage de 1/8 po (3 mm) aux endroits marqus. Delivery is only applicable within the contiguous United States. Always remove the boat from the water before using 120V AC power tools. 8 aus rostfreiem Stahl. Product : ATTWOOD TSUNAMI REPLACEMENT MOTOR CARTRIDGE F/ T500 Manufacture- SKU: CW46477 Attwood T500 Manual Pump Cartridge Motor Replacement: Fits T500, T800 and T1200 Tsunami Bilge Pumps and Aerator Pumps Twist and lock design for easy replacement 12-Volts 36" Wire T1200 Tsunami Bilge Pump With their innovative engineering and compact design, Tsunami pumps deliver high output from a small package. For more information go to Proposition 65 Warnings Website. For automatic operation, use Attwood Automatic Float. (Figura 2). 8 in passender Lnge fr die Montageche, Schlauchklemmen (Attwood Teilenummer 9185, 2 pro Anschluss), Grundplatte: Sperrholz fr Schiffsanwendungen, Glasfasermatte und Harz), Manuellen (Teilenummer 7615A) oder automatischen Schwimmschalter (Teilenummer 4201 oder 4202), Gegen Treibstoff widerstandsfhigen, verstrkten Auslassschlauch mit glattem Innendurchgang. Patented shaft seal prevents leaks caused by misalignmentplus caulked and tinned wiring eliminates wicking, prevents water damage and resists corrosion. 1.Conecte el cable positivo (marrn) al interruptor. Drill three 1/8" (3 mm) pilot holes at marked locations. Applicera marint ttningsmedel kring skrovgenomfringens nsar p skrovet inoch utsida. Practical Design. (Figure 2), Make all wire connections above the highest water level. Use marine, grade wire connectors only. Make all wire connections above the highest water level. Sized to match Attwood T500, T800, and T1200 bilge pumps. WICHTIG: Um Luftblasen zu verhindern, muss der Schlauch ohne Senke oder scharfe Biegungen stetig aufwrts zur Rumpfdurchfhrung verlegt werden. 2.Mit dem Sockel als Vorlage markieren Sie die drei Montagelcher auf der Montageplatte. 3.Om ingen skrovgenomfring nns, montera en minst 12 tum (30,5 cm) ovanfr vattenlinjen. Ls alla anvisningar noggrant innan denna produkt monteras och anvnds. Om anslutningarna kastas om frsmras funktionen och pumpen kan g snder. Patented X-Air Impeller ejects trapped air in the pump and pipework. Remove base. Tsunami T500 Aerator Pump | West Marine test system, feed water into the pump. 2.Anvnd sockeln som mall fr att mrka ut tre monteringshl i monteringsunderlaget. 5.Fixez la pompe sur sa base. Faites tourner le botier dans le sens contraire des aiguilles dune montre et retirez le botier de sa base. (Figure 2), Effectuez toutes les connexions de ls au-dessus du plus haut niveau de ottaison. Before drilling be sure mountedpump will be correctly positioned with pump nozzle pointing towardthru-hull connector. Motor cartridge unlocks for easy cleaning and maintenance. Install fuse holder within 72in (183 cm) of the positive battery terminal. (Figure 3). (Figure 1). Required fields are marked *. Twist counter-clockwise and remove pump housing from base. Lea atentamente todas las instrucciones antes de instalar y utilizar este producto. Fst med rostfria stlfstdon (nr 8). Instale el ltro de base en una almohadilla de montaje de madera contrachapada nutica con bra de vidrio hasta el casco. No estn pensadas para evitar la rpida acumulacin de agua en el bote debido a condiciones climticas adversas, daos en el casco u otras condiciones de navegacin inseguras. 2.berprfung des richtigen Motorgehuses: Siehe Tabelle der technischen Daten wegen der Teilenummer eines AustauschMotorgehuses. Attwood is part ofNavico GroupbyBrunswick. The Offshore Stream provides an industry-leading, 4 feet of floor space per passenger. 2.Check motor cartridge t: See specication chart for replacement motor cartridge number. Befestigen Sie den geschlitzten Sockel auf einer Grundplatte aus Sperrholz fr Schiffsanwendungen, welche mit einer Glasfasermatte und Harz am Rumpf befestigt wurde. The Superior Life-Saving Equipment HALO is the perfect life raft for smaller vessels or coastal boaters. Use base as template to mark 3 mounting holes in mounting pad. Use base as template to mark 3 mounting holes in mounting pad. Tsunami Cartridge Motor Replacements : Attwood Marine Attwood Tsunami T500 Bilge Pump, 500 GPH, 12-Volt, Barbed -Inch Diameter Outlet, 29-Inch Wire. Tsunami Mk2 is the easiest manual bilge pump to install and service Tsunami Mk2 is the most reliable manual bilge pump in freshwater applications Key Features External mounting feet and integrated outlet reduces time and effort. Remove base. Retire el bote del agua antes de usar herramientas elctricas de 120 voltios de CA. 1.Halten Sie das Pumpengehuse fest, drcken Sie die Haltelasche des Motorgehuses hinein. (Figure 1). Attwood Tsunami MK2 T500 Manual Bilge Pump w/Installation Kit - 500 GPH Attwood. Disconnect power to the pump. Nichtbeachten kann zu schweren Verletzungen oder zu Feuergefahr fhren. Halten Sie das Pumpengehuse fest, drcken Sie die Haltelasche des Motorgehuses hinein. Der Motor muss der Farbe des Gehuses entsprechen: Serie 500 = ROT, 800 = BLAU, 1200 = GRAU. Form Number 69390 Rev. Drei Edelstahlschrauben Nr. 4.Replace base. Switch (#4201 or 4202). In this video I cover how to install a Tsunami T500 Aerator Pump and a general idea on how to install any brand of aerator pumps! SUBSCRIBE https://www.youtube.com/channel/UCqQ0vvJEoZceOIEJyPZqknA?sub_confirmation=1*FOLLOW ME ON SOCIAL MEDIA! Esta bomba de sentina Attwood tiene una garanta limitada de tres (3) aos. Reliez le l ngatif (noir) la mise la terre. 3.Pour rinstaller la cartouche : enrobez un joint torique dhuile vgtale (les huiles base de ptrole causent la dtrioration). Orient pump outlet for a direct, unobstructed hose path. Also, the Tsunami Mk2 is the most reliable manual bilge pump in freshwater applications, considering it has 40% better protection against water ingress and electrolysis vs. the Mk1 pump. . The double-filter base resists clogging, and no mounting brackets are necessary for installation. Add extra coverage from the date of purchase beyond the manufacturers warranty. Stellen Sie sicher, dass der Schlauch immer aufwrts ohne Senken zur Rumpfdurchfhrung fhrt (Abbildung 1). Insrtela en la base y gire en sentido horario hasta que la lengeta se trabe y quede rme. 2.Ne pas monter la pompe directement sur la coque. attwood 4614-7 Bilge Pump Installation Kit, with Tsunami Para el funcionamiento automtico, utilice el interruptor otante automtico de Attwood (pieza N. 4201 4202). On sailboats, location should be centered over keel. Attach with #8 stainless steel fasteners. Percez trois orices de guidage de 1/8 po (3 mm) aux endroits marqus. P segelbtar ska den centreras ver klen. Fr automatischen Betrieb verwenden Sie einen automatischen Schwimmschalter (Teilenummer 4201 oder 4202). Alle Verbindungen mssen mit Schlauchklemmen xiert werden. No es necesario retirar el cartucho del motor para la instalacin. Anslut den negativa ledaren (svart) till jord. Regularly inspect and clean to be sure that debris is not blocking the, Check for airlock. Replace base. NOTE: Failure to make waterproof connections and fuse pump properly will void the product warranty. Installation Guide for Attwood Tsunami Bilge Pumps To access mounting holes, remove base strainer. WARNING Si la bomba funciona pero no extrae agua: 1.Verique que no haya bolsas de aire. (Figure 1). C 08-08 2008 Attwood Corporation 1016 N. Monroe Street, Lowell, MI 49331-0260 www .attwoodmarine.com W ARNING Read all instructions carefully before installing and using this product. Utilice un fusible elctrico de tubo de vidrio de tipo automotriz estndar (SAE J554). Bilge Pump Installation Kit. Signature required for receipt of shipment. Avant le perage, assurez-vous que la pompe xe en place sera correctement positionne avec la buse de la pompe oriente vers le raccord passe-coque. 3.If no thru-hull connector exists, install at 12" min. Falls der Aususs gering erscheint, berprfen Sie die Drahtverbindungen. (Figura 2), BOMBAS DE SENTINA ATTWOOD DE GARANTA LIMITADA. C 08-08 2008 Attwood Corporation 1016 N. Monroe Street, Lowell, MI 49331-0260 www.attwoodmarine.com WARNING Read all instructions carefully before installing and using this product. (Figure 1) Do not mount pump directly to hull. The Tsunami Mk2 is the only manual bilge pump that eliminates airlocks. Attwood bilge pumps are designed to exhaust STANDING WATER, ONLY. Rugged glass and mineral-filled polymer construction resists fuel, detergent, and chemicals. HOSE CONNECTION INSTRUCTIONS IMPORTANT: To prevent airlock, hose must rise continually upward to the thru-hull connector with no dips or sharp bends. The insulated double inflatable floor provides hypothermia protection and the two canopy openings offer an excellent Superior Lifesaving Equipments Offshore Stream is the quintessential offshore liferaft, suitable for any recreation boater looking to travel beyond the coastline. (Figure 3), Failure to make waterproof connections and fuse pump properly will void the product warranty, Connect positive lead (brown) to switch. To install, simply align motor cartridge tab with housing slot and twist to lock. Installation Guide for attwood models including: 500 GPH Bilge Pump and Installation Kit, GPH Bilge Pump and Installation Kit, Pump and Installation Kit, Installation Kit, Kit, Attwood Tsunami MK2 T500 Manual Bilge Pump w/Installation Kit - 500 GPH & 12V ATTWOOD MARINE5614-7, Attwood Tsunami MK2 T500 Manual Bilge Pump w/Installation Kit - 500 GPH & 12Vmanuals.plusattwoodattwood 500 GPH Bilge Pump and Installation Kit Installation Guide, File Info : application/pdf, 1 Pages, 1.14MB, attwood 500 GPH Bilge Pump and Installation Kit Installation Guide. They are not intended to prevent rapid accumulation of on-board water due to rough weather, hull damage, and/or other runsafe navigational conditions. Tsunami Pump Cartridge Replacements | West Marine Skra samtliga anslutningar med slangklmmor. Attwood uses the most advanced material available, including the best quality bearings and state-of-the-art brushes, alloys and magnets. Consultez le tableau des spcications pour vous assurer davoir choisi la pompe qui vous convient : Trois attaches No 8 en acier inoxydable, de longueur convenant la surface de xation, Perceuse sans cordon avec fraise de 1/8 po (3 mm), Colliers de serrage pour tuyaux (Attwood No 9185, deux par raccord), Tampon de xation : contreplaqu marin, toile de bre de verre et rsine, Interrupteur otteur manuel (No 7615A) ou automatique (No 4201 ou 4202), Boyau de sortie rsistant au carburant, renforc, intrieur lisse, 1.Placez la pompe dans lespace accessible le plus bas dans la cale. If you would like to change your settings or withdraw consent at any time, the link to do so is in our privacy policy accessible from our home page.. This replacement cartridge motor fits the T500 Tsunami Bilge Pump and Aerator Pump. (gur 1). NO utilice la bomba para extraer gasolina, aceite u otros lquidos inamables. This is done by the Patented X-Air Impeller, which ejects trapped air in the pump and pipework. reinstall cartridge: Coat O-ring with vegetable oil (petroleum-based oils will cause deterioration). On sailboats, location should be centered over keel. Additional shipping fees apply. Para colocar nuevamente el cartucho: cubra la junta trica con una capa de aceite vegetal (los aceites a base de petrleo la daarn). View and Download Attwood T500 instruction manual online. 1.Apunte la salida de la bomba de manera tal que la manguera no se vea obstruida. 0:00 / 13:00 How to Install a Livewell Pump! (Figure 2) 3. Diese Lenzpumpe von Attwood besitzt eine dreijhrige Garantie. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound. Manage Settings ATTENTION : ne pas percer la coque. Insrtela en la base y gire en sentido horario hasta que la lengeta se trabe y quede rme. Reversed wiring reduces per, Disconnect power to the pump. Please call us at: 1-800-HOME-DEPOT (1-800-466-3337), Please enter in your email address in the following format: you@domain.com. Perfore tres agujeros gua de 3 mm en las ubicaciones marcadas. Attach base strainer to a marine plywood mounting pad that is berglassed to the hull. Attwood Resources Be sure that outlet hose runs upward to the thru-hull connector, with no dips. The cookie settings on this website are set to "allow all cookies" to give you the very best experience. 2.Install fuse holder within 72" (183 cm) of the positive (+) battery terminal. Install fuse holder within 72" (183 cm) of the positive (+) battery terminal. To access mounting holes, remove base strainer. Om inte anslutningarna grs korrekt och pumpen avskras korrekt gller inte produktgarantin. 40% better protection against water ingress and electrolysis - vs. Mk1. Attwood Remote Bracket see Accessories Chart for size. Faites tourner le botier dans le sens contraire des aiguilles dune montre et retirez le botier de sa base. Faites-la tourner dans le sens des aiguilles dune montre jusqu ce que vous entendiez la languette senclencher dans la fente. Can be used for both bilge and bait pumps. (Figura 1). Anslut den positiva ledaren (brun) till strmbrytaren. Si lcoulement semble bas. Fr automatisk funktion, anvnd Attwoods automatiska nivvakt (nr 4201 eller 4202). (Figure 3). Three #8 stainless fasteners, suitable length for mounting surface, Hose clamps (Attwood # 9185, 2 per connection), Mounting pad: marine plywood, berglass cloth and resin, Manual (# 7615A) or automatic oat switch (#4201 or 4202), Position pump in the lowest accessible part of the bilge. Our leading fish-friendly technology is making it easier to install and service, while offering new installation options never before provided by the Tsunami range. Drehen Sie entgegen dem Uhrzeigersinn (Abbildung 2). T, vicing this product. Retirez les dbris de la chambre et de la tte de pompe. Specifications: Flow Rate: 498 GPH (8.3 GPM) Inlet Length: 1-1/2" Inlet Diameter: 3/4" D Outlet Connection: 3/4" Threaded Rated Voltage: 12 V Wire/Connector: 29" Wire Length: 1-1/2" hose outlet. If ow appears low, be sure wires have been connected properly: Brown-to-positive (switch), and black-to-negative. IMPORTANTE: Si las conexiones a prueba de agua no son las adecuadas y no se conecta la bomba al fusible de forma correcta, se anular la garanta del producto. Does not apply to Truck Freight orders or hazardous orders. Fatta pumphuset, tryck ned motorpatroniken och vrid sedan patronen moturs fr att avlgsna den (gur 2). Consulte el cuadro de especicaciones para asegurarse de haber seleccionado la bomba adecuada: Tres sujetadores de acero inoxidable N. 8 de longitud adecuada para la supercie de montaje, Abrazaderas para manguera (2 piezas Attwood N. 9185 por conexin), Almohadilla de montaje: madera contrachapada nutica, tela de bra de vidrio y resina, Interruptor manual (pieza N. 7615A) o otante automtico (pieza N. 4201 4202), Manguera de salida de nima lisa reforzada y resistente al combustible, 1.Coloque la bomba en el extremo inferior ms accesible de la sentina. Easy to remove and clean. Stellen Sie sicher, dass der Rotor fest sitzt und nicht beschdigt oder gebrochen ist (Abbildung 2). hose outlet. Elles ne sont pas conues pour prvenir laccumulation rapide deau bord cause de trs mauvais temps, de dommages la coque et (ou) dautres conditions de navigation peu sres. (Figure 3). Asegrese de que las conexiones elctricas y el fusible sean a prueba de agua y que no se hayan aojado. Anvnd endast kabelkontakter fr marint bruk. Available for 1-day shipping 1-day shipping. 1.Orient pump outlet for a direct, unobstructed hose path. Inserte el cartucho en el bastidor. Tilt. Comment * document.getElementById("comment").setAttribute("id","abcc6481e0b239554751733f97ea206e");document.getElementById("afe6277d1c").setAttribute("id","comment"); Save my name, email, and website in this browser for the next time I comment. (gur 1). Skerstll att utloppsslangen r riktad uppt mot skrovgenomfringen och inte hnger. 1.Check for airlock. Position pump in the lowest accessible part of the bilge. They are not intended to prevent rapid accumulation of on-board water due to rough weather, hull damage, and/or other unsafe navigational conditions. To prevent personal injury, disconnect the power source when installing or servicing this . Si observa un ujo bajo, asegrese de que los cables estn conectados de forma correcta: el cable marrn al terminal positivo (interruptor) y el cable negro al terminal negativo. Motorpatronen behver inte avlgsnas vid monteringen. Il nest pas ncessaire denlever la cartouche du moteur pour linstallation. It is not necessar, to remove motor cartridge for installation. 3.Zum Testen fhren Sie der Pumpe Wasser zu. Apply marine sealant around thru-hull flanges on interior and exterior of hull. Local store prices may vary from those displayed. 2.Secure all connections with hose clamps. Installation instructions Attwood 4640 Installation Instructions Tsunami aerator pump 1 2 page of 2 Bookmarks Advertisement Download this manual 3 Tsunami Aerator Pump Installation Instructions SAVE THESE INSTRUCTIONS Form Number 69391 Rev. **West Marine pickup in store order must be placed 2 hours before local store closing time to be eligible. Befestigen Sie ihn mit drei Schrauben Nr. On, sailboats, location should be centered over keel. (Figure 2), Make all wire connections above the highest water level. 4.Insrez la cartouche dans le botier. Insert into base, twist clockwise until tab snaps in and prevents turning. Borra inte igenom skrovet. IMPORTANTE: Para evitar las bolsas de aire, la manguera debe colocarse en direccin ascendente respecto del conector de casco pasante y no debe estar inclinada ni doblada de forma pronunciada. (Figure 2). (Figura 3). Om pumpen krs utan att ngot vatten pumpas ut: 1.Kontrollera om luftls frekommer. To prevent personal injury, disconnect the power source when installing or servicing this product. Attwood Marine MK2 T500 Manual Bilge Pump w/Installation De r inte avsedda att frhindra snabb ansamling av vatten ombord p.g.a. 4.Inserte el cartucho en el bastidor. from the water before using 120V AC power tools. Kontrollera skringen. If flow appears low, be sure wires have been connected properly: Brown-to-positive (switch), and black-to-negative. This user manual for Attwood Marine's MK2 T500 Manual Bilge Pump w/Installation Kit provides complete instructions for the installation of the pump and accessories. (gur 2), Gr samtliga trdanslutningar ovanfr den hgsta vattenlinjen. 3.Um das Motorgehuse wieder zu installieren: Schmieren Sie den O-Ring mit Panzenl (l auf Petroleum-Basis wrde zu Zersetzungen fhren). Vriez si la cartouche convient bien : consultez le tableau des spcications pour vous procurer la bonne cartouche de moteur de rechange. https://youtu.be/ogXdJPJBJCgPRODUCTS AND ACCESSORIES :Attwood Tsunami T500 Aerator Pump - 12Vhttps://www.amazon.com/gp/product/B00FFA93US/ref=ppx_yo_dt_b_asin_title_o03__o00_s00?ie=UTF8\u0026psc=1Aerator Screen Strainerhttps://www.amazon.com/gp/product/B001441FZU/ref=ppx_yo_dt_b_asin_title_o04__o00_s01?ie=UTF8\u0026psc=13M Marine Adhesive/Sealant Fast Cure 4200https://www.amazon.com/gp/product/B0000AY6B0/ref=ppx_yo_dt_b_asin_title_o04__o00_s01?ie=UTF8\u0026psc=13/4\" Clear Flexible PVC Tubinghttps://www.amazon.com/gp/product/B00LX6MFYE/ref=ppx_yo_dt_b_asin_title_o01__o00_s00?ie=UTF8\u0026psc=1#tsunamiaeratorpump#howto#redbeardoutdoors#livewellupgrades#boatupgrades We use the most advanced material available, including the best quality bearings and state-of-the-art brushes, alloys and magnets. 8 in passender Lnge fr die Montageche, Akku-Bohrmaschine mit 3 mm (1/8 Zoll) Bohrer, Schlauchklemmen (Attwood Teilenummer 9185, 2 pro Anschluss), Grundplatte: Sperrholz fr Schiffsanwendungen, Glasfasermatte und Harz), Manuellen (Teilenummer 7615A) oder automatischen Schwimmschalter (Teilenummer 4201 oder 4202), Gegen Treibstoff widerstandsfhigen, verstrkten Auslassschlauch mit glattem Innendurchgang. 5. If you do not receive an email contact Customer Service. Kontrollera att motorpatronen passar: Se specikationstabellen fr rtt nummer p ersttningsmotorpatronen. Instale el ltro de base en una almohadilla de montaje de madera contrachapada nutica con bra de vidrio hasta el casco. (Figure 2), 1. Orient pump outlet for a direct, unobstructed hose path. Skydda alla anslutningar med lmpliga material. Utilice solamente conectores de grado nutico. PDF T500 Recirq Livewell Aerator Kit - Attwood Marine Products *FREE STANDARD SHIPPING applicable on orders over $99.00 within the 48 contiguous United States. 3.Si no hay ningn conector de casco pasante, instale uno a 30.5 cm como mnimo por sobre la lnea del agua. Entfernen Sie Abfall aus der Kammer und vom Rotor. 1.Fatta pumphuset, tryck ned motorpatroniken och vrid sedan patronen moturs fr att avlgsna den (gur 2). To test system, feed water into the pump. Be sure electrical connections and fuse are waterproof and havent loosened. Drehen Sie gegen den Uhrzeigersinn und entfernen Sie das Pumpengehuse vom Sockel. Failure to do so could result in serious personal injury or fire hazards. tre rostfria fstdon (nr 8), lmplig lngd fr monteringsunderlaget, slangklmmor (Attwood nr 9185, 2 per anslutning), monteringsunderlag: marin plywood, glasbervv och harts, manuell (nr 7615A) eller automatisk nivvakt (nr 4201 eller 4202), Placera pumpen i klens lgsta, tkomliga del. Tsunami Aerator Pumps T500, T800, T1200 With their innovative engineering and compact design, Tsunami pumps deliver high output from a small package. Stellen Sie sicher, dass die elektrischen Verbindungen und die Sicherung wasserfest sind und sich nicht gelst haben (Abbildung 3). Drill three 1/8" (3 mm) pilot holes at marked locations. Connect positive lead (brown) to switch. De lo contrario, esto puede ocasionar lesiones personales graves o peligros de incendio. Always use the fuse amperage rating specified for your pump model. 3. Tenez le botier de la pompe, appuyez sur la languette de la cartouche du moteur et faites tourner la cartouche dans le sens contraire des aiguilles dune montre pour lenlever (Figure 2). It is not necessary to remove motor cartridge for installation. Purchase online, in stores or call 1 (800) 262-8464. Bilge pump installation kit complete kit with tsunami t 500 bilge pump. Using the most advanced material available, including the best quality bearings and state-of-the-art brushes, alloys and magnets. Fjela con sujetadores de acero inoxidable N. 8.
Harley Hidden Trailer Hitch, Wrought Iron Fence Parts Near Me, Best Tom Suspension Mount, Klean Kanteen 40 Oz Classic, Cleveland Chipper Black, Specialized Altered Trail Rain Jacket, Inflatable Pool Noodle, Shower Shoes Vs Flip Flops, Low Rise Wide Leg Cropped Jeans,